Model | Article no. | Declaration of performance |
---|---|---|
CAQ350-L-PH-STT-GB - Zehnder ComfoAir Q350 with Pre-Heater, Left Handed | 471502017 | 1603044Q35010.pdf(47 KB) |
Control | Energy class | Energy label |
Energy Label – Central demand control | EU-label_CAQ350_471502017_A+.pdf(97 KB) | |
Energy Label – Manual control | GB-label_CAQ350_471502017_A.pdf(91 KB) | |
Energy Label – Local demand control | EU-label_CAQ350_471502017_A+.pdf(97 KB) | |
Energy Label – Clock control | GB-label_CAQ350_471502017_A.pdf(91 KB) |
Label | Value |
---|---|
Catalogue number | 471502017 |
GTIN | 8717573874373 |
Production model | COMFOAIR Q350 GB L PH ST |
Air flow rate | 350 m³/h |
Amperage | 7.6 A |
Supply voltage | 230 V |
Frequency | 50 Hz |
Noise/Sound Level | 40 |
Energy class I | A |
Energy class II | A+ |
Left/right orientation reversible | |
Heat recovery by | Cross-counter-flow unit |
Efficiency supply filter according to ISO 16890-1:2016 | 55 % |
Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
Connections outdoor air side | Insert-/duct end |
With internal humidity (RH) sensor | |
Type of speed control | Other |
With heating element | |
Nominal duct diameter | 160-190 mm |
Suitable for wall mounting | |
With thermal overload protection | |
Nominal duct diameter | 160-190 mm |
Height | 850 mm |
Max. air volume at 50 Pa | 245 m³/h |
Max. air volume at 100 Pa | 350 m³/h |
Suitable for wired control unit | |
With bypass | |
Voltage | 230 V |
Material housing | Steel coated |
With wired control unit | |
With zone controller | |
Thermal efficiency at 70 % air volume at 50 Pa | 94 % |
Suitable for floor mounting | |
Heat recovery by | Cross-counter-flow unit |
Number of phases | 1 |
Housing material quality | Other |
Electrical connection | Connecting cable with plug with protective contact |
Width | 725 mm |
Suitable for extra VOC sensor | |
Type of frost protection | Heating element |
Depth | 570 mm |
With heating element | |
Material heat exchanger | Other |
Fuse size of the device | 10 A |
Thermal efficiency at 70 % air volume at 50 Pa | 94 % |
Suitable for central heating boiler connection | |
Suitable for (extra) carbon dioxide (CO2) sensor | |
Roof connection, top | |
Frequency | 50 Hz |
Roof connection, side | |
Operation by app | |
Voltage | 230 V |
Material heat exchanger | Other |
Type of motor | Electronically commutated (EC) |
Max. air volume at 200 Pa | 350 m³/h |
With volatile organic compound (VOC) sensor | |
Power consumption at max. air volume at 100 Pa | 0.101 kW |
Max. air volume at 150 Pa | 350 m³/h |
Type of motor | Electronically commutated (EC) |
Residential connection, left side | |
Energy efficiency class | A+ |
Residential connection, underside | |
Supporting protocol for Modbus | |
Residential connection, top | |
Suitable for zone controller | |
Residential connection, right side | |
Connections outdoor air side | Insert-/duct end |
Suitable for wireless remote control | |
With constant pressure control | |
Number of phases | 1 |
Width | 725 mm |
Connections residential side | Insert-/duct end |
Cos phi according to EPN standard | 0.42 |
Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
With digital display | |
Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
Depth | 570 mm |
Supply filter according to ISO 16890-1:2016 | ISO ePM1 |
Height | 850 mm |
Suitable for (extra) humidity (RH) sensor | |
Degree of protection (IP) | IP40 |
Thermal efficiency according to EPN standard | 94 % |
Suitable for zone controller | |
Power input according to EPN standard | 0.086 kW |
Suitable for wired control unit | |
Weight | 52 kg/100 m |
With bypass | |
Efficiency supply filter according to ISO 16890-1:2016 | 55 % |
Suitable for wall mounting | |
Suitable for (extra) carbon dioxide (CO2) sensor | |
With thermal overload protection | |
Housing material quality | Other |
Suitable for floor mounting | |
Weight | 52 kg |
Suitable for central heating boiler connection | |
Frequency | 50 Hz |
Max. air volume at 100 Pa | 350 m³/h |
Housing material | Steel |
Suitable for wireless remote control | |
Suitable for ceiling mounting | |
With digital display | |
Suitable for ceiling mounting | |
Residential connection, left side | |
Left/right orientation reversible | |
Residential connection, underside | |
Power consumption at max. air volume at 100 Pa | 0.101 kW |
Residential connection, top | |
Energy efficiency class (1253/2014/EU) | A+ |
Residential connection, right side | |
Electrical connection | Connecting cord with plug with protective contact |
Roof connection, top | |
Housing material | Steel |
Roof connection, side | |
Suitable for extra VOC sensor | |
Max. air volume at 150 Pa | 350 m³/h |
Energy efficiency class according to 1253/2014/EU | A+ |
Max. air volume at 200 Pa | 350 m³/h |
Max. air volume at 50 Pa | 245 m³/h |
Width | 725 mm |
Electrical connection | Connecting cord with plug with protective contact |
Nominal duct diameter | 160-190 mm |
With internal carbon dioxide (CO2) sensor | |
Height | 850 mm |
Type of motor | Electronically commutated (EC) |
Depth | 570 mm |
With zone controller | |
Supply filter according to ISO 16890-1:2016 | ISO ePM1 |
With wired control unit | |
Voltage | 230 V |
With volatile organic compound (VOC) sensor | |
Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
Degree of protection (IP) | IP40 |
Weight | 52 kg |
Fuse size of the device | 10 A |
With internal humidity (RH) sensor | |
Supporting protocol for Modbus | |
Suitable for (extra) humidity (RH) sensor | |
With constant volume flow control | |
Frequency | 50 Hz |
Connections residential side | Insert-/duct end |
With constant pressure control | |
Power electric heating element | 0-1740 W |
With constant volume flow control | |
With internal carbon dioxide (CO2) sensor | |
Type of frost protection | Heating element |
Power electric heating element | 0-1740 W |