Comfoair200, CA200, Comfopipe150, CP150, ComfoSilence, silencer, ambience, living room, table, chair, milieu
Article no. 471226315

Zehnder ComfoAir 200 Luxe with Pre-Heater, Right Handed

    Declaration

    ModelArticle no.Declaration of performance
    CA200-LX-R-PRH-ND-GB-MC3 - Zehnder ComfoAir 200 Luxe with Pre-Heater, Right Handed471226315 1511044200010.pdf(48 KB)
       
    ControlEnergy classEnergy label
    Energy Label – Central demand control EU-Label_CA200_471226315_A.pdf(95 KB)
    Energy Label – Manual control EU-Label_CA200_471226315_A.pdf(95 KB)
    Energy Label – Local demand control GB-EU-Label_CA200_471226315_A+.pdf(142 KB)
    Energy Label – Clock control EU-Label_CA200_471226315_A.pdf(95 KB)

    Data Table

    LabelValue
    Catalogue number 471226315
    GTIN 5030216110236
    Production model COMFOAIR200 GB R LUXE PH
    Air flow rate 230 m³/h
    Amperage 6.97 A
    Supply voltage 230 V
    Frequency 50 Hz
    Noise/Sound Level 40
    Energy class I A
    Energy class II A+
    Thermal efficiency at 70 % air volume at 50 Pa 93.3 %
    Energy efficiency class (1253/2014/EU) A+
    Max. air volume at 50 Pa 225 m³/h
    Max. air volume at 100 Pa 230 m³/h
    Suitable for wall mounting
    Residential connection, underside
    Weight 33.73 kg
    Left/right orientation reversible
    Exhaust filter according to ISO 16890-1:2016 ISO Coarse
    Nominal duct diameter 125-160 mm
    Height 1108 mm
    Supply filter according to ISO 16890-1:2016 ISO Coarse
    Depth 321 mm
    With thermal overload protection
    Power input according to EPN standard 0.0384 kW
    Type of motor Electronically commutated (EC)
    With digital display
    Electrical connection Connecting cord with plug with protective contact
    Suitable for floor mounting
    Nominal duct diameter 125-160 mm
    Roof connection, side
    Suitable for wall mounting
    Supporting protocol for Modbus
    Frequency 50 Hz
    Max. air volume at 200 Pa 185 m³/h
    Type of speed control Other
    Housing material Steel
    Max. air volume at 100 Pa 230 m³/h
    Power electric heating element 730-785 W
    Connections residential side Insert-/duct end
    Thermal efficiency according to EPN standard 93.3 %
    Connections outdoor air side Insert-/duct end
    Number of phases 1
    With bypass
    With constant volume flow control
    Material housing Steel coated
    With internal humidity (RH) sensor
    With wired control unit
    Exhaust filter according to ISO 16890-1:2016 ISO Coarse
    Suitable for (extra) humidity (RH) sensor
    Suitable for wireless remote control
    With internal humidity (RH) sensor
    Residential connection, right side
    Suitable for zone controller
    With thermal overload protection
    With zone controller
    Suitable for wired control unit
    Suitable for wired control unit
    Connections outdoor air side Insert-/duct end
    Max. air volume at 250 Pa 160 m³/h
    Type of frost protection Heating element
    Suitable for floor mounting
    Weight 33.73 kg
    Material heat exchanger Other
    Electrical connection Connecting cord with plug with protective contact
    Max. air volume at 50 Pa 225 m³/h
    With volatile organic compound (VOC) sensor
    Width 535 mm
    Supporting protocol for Modbus
    Suitable for (extra) carbon dioxide (CO2) sensor
    Suitable for ceiling mounting
    With constant pressure control
    With heating element
    With bypass
    Suitable for (extra) humidity (RH) sensor
    Efficiency exhaust filter according to ISO 16890-1:2016 65 %
    Suitable for central heating boiler connection
    Supply filter according to ISO 16890-1:2016 ISO ePM1
    Roof connection, top
    Suitable for (extra) carbon dioxide (CO2) sensor
    Roof connection, side
    Residential connection, left side
    Residential connection, top
    Roof connection, top
    Number of phases 1
    Max. air volume at 250 Pa 160 m³/h
    Suitable for central heating boiler connection
    With internal carbon dioxide (CO2) sensor
    With zone controller
    Max. air volume at 200 Pa 185 m³/h
    With wired control unit
    Suitable for zone controller
    Max. air volume at 150 Pa 210 m³/h
    Connections residential side Insert-/duct end
    Energy efficiency class A+
    Max. air volume at 150 Pa 210 m³/h
    Residential connection, left side
    With internal carbon dioxide (CO2) sensor
    Residential connection, underside
    Voltage 230 V
    Residential connection, top
    Degree of protection (IP) IP44
    Residential connection, right side
    Efficiency supply filter according to ISO 16890-1:2016 65 %
    Suitable for wireless remote control
    Frequency 50 Hz
    Heat recovery by Cross-counter-flow unit
    Width 535 mm
    Power consumption at max. air volume at 100 Pa 0.143 kW
    Cos phi according to EPN standard 0.53
    Housing material quality Other
    Depth 321 mm
    Type of motor Electronically commutated (EC)
    Efficiency exhaust filter according to ISO 16890-1:2016 65 %
    Max. air volume at 300 Pa 135 m³/h
    Height 1108 mm
    Suitable for extra VOC sensor
    Voltage 230 V

    Downloads