Model | Article no. | Declaration of performance |
---|---|---|
CA200-LX-R-PRH-ND-GB-MC3 - Zehnder ComfoAir 200 Luxe with Pre-Heater, Right Handed | 471226315 | 1511044200010.pdf(48 KB) |
Control | Energy class | Energy label |
Energy Label – Central demand control | EU-Label_CA200_471226315_A.pdf(95 KB) | |
Energy Label – Manual control | EU-Label_CA200_471226315_A.pdf(95 KB) | |
Energy Label – Local demand control | GB-EU-Label_CA200_471226315_A+.pdf(142 KB) | |
Energy Label – Clock control | EU-Label_CA200_471226315_A.pdf(95 KB) |
Label | Value |
---|---|
Catalogue number | 471226315 |
GTIN | 5030216110236 |
Production model | COMFOAIR200 GB R LUXE PH |
Air flow rate | 230 m³/h |
Amperage | 6.97 A |
Supply voltage | 230 V |
Frequency | 50 Hz |
Noise/Sound Level | 40 |
Energy class I | A |
Energy class II | A+ |
Thermal efficiency at 70 % air volume at 50 Pa | 93.3 % |
Energy efficiency class (1253/2014/EU) | A+ |
Max. air volume at 50 Pa | 225 m³/h |
Max. air volume at 100 Pa | 230 m³/h |
Suitable for wall mounting | |
Residential connection, underside | |
Weight | 33.73 kg |
With volatile organic compound (VOC) sensor | |
Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
Nominal duct diameter | 125-160 mm |
Height | 1108 mm |
Supply filter according to ISO 16890-1:2016 | ISO Coarse |
Depth | 321 mm |
Nominal duct diameter | 125-160 mm |
With thermal overload protection | |
Frequency | 50 Hz |
Type of motor | Electronically commutated (EC) |
With constant volume flow control | |
Electrical connection | Connecting cord with plug with protective contact |
Suitable for floor mounting | |
Nominal duct diameter | 125-160 mm |
Roof connection, side | |
Suitable for wall mounting | |
Supporting protocol for Modbus | |
Frequency | 50 Hz |
Max. air volume at 200 Pa | 185 m³/h |
Type of speed control | Other |
Housing material | Steel |
Max. air volume at 100 Pa | 230 m³/h |
Power electric heating element | 730-785 W |
Connections residential side | Insert-/duct end |
Depth | 321 mm |
Connections outdoor air side | Insert-/duct end |
Width | 535 mm |
With bypass | |
Electrical connection | Cable |
Material housing | Steel coated |
Voltage | 230 V |
With wired control unit | |
Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
Suitable for (extra) humidity (RH) sensor | |
Suitable for wireless remote control | |
With internal humidity (RH) sensor | |
Residential connection, right side | |
Suitable for zone controller | |
With thermal overload protection | |
With zone controller | |
Suitable for wired control unit | |
Suitable for wired control unit | |
Connections outdoor air side | Insert-/duct end |
Max. air volume at 250 Pa | 160 m³/h |
Type of frost protection | Heating element |
Suitable for floor mounting | |
Weight | 33.73 kg |
Material heat exchanger | Other |
Electrical connection | Cable |
Max. air volume at 50 Pa | 225 m³/h |
With volatile organic compound (VOC) sensor | |
Height | 1108 mm |
Width | 535 mm |
Thermal efficiency at 70 % air volume at 50 Pa | 93 % |
Suitable for (extra) carbon dioxide (CO2) sensor | |
Operation by app | |
Heat recovery by | Cross-counter-flow unit |
Energy efficiency class according to 1253/2014/EU | A |
Degree of protection (IP) | IP44 |
With constant pressure control | |
Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
Suitable for central heating boiler connection | |
Supply filter according to ISO 16890-1:2016 | ISO Coarse |
Roof connection, top | |
Suitable for (extra) carbon dioxide (CO2) sensor | |
Roof connection, side | |
Residential connection, left side | |
Residential connection, top | |
Roof connection, top | |
Number of phases | 1 |
Max. air volume at 250 Pa | 160 m³/h |
Suitable for central heating boiler connection | |
With internal carbon dioxide (CO2) sensor | |
With zone controller | |
Max. air volume at 200 Pa | 185 m³/h |
With wired control unit | |
Suitable for zone controller | |
Max. air volume at 150 Pa | 210 m³/h |
Connections residential side | Insert-/duct end |
Energy efficiency class | A+ |
Max. air volume at 150 Pa | 210 m³/h |
Residential connection, left side | |
With internal carbon dioxide (CO2) sensor | |
Residential connection, underside | |
Voltage | 230 V |
Residential connection, top | |
Degree of protection (IP) | IP44 |
Residential connection, right side | |
Efficiency supply filter according to ISO 16890-1:2016 | 65 % |
Suitable for wireless remote control | |
Frequency | 50 Hz |
Heat recovery by | Cross-counter-flow unit |
Width | 535 mm |
Power consumption at max. air volume at 100 Pa | 0.143 kW |
Cos phi according to EPN standard | 0.53 |
Housing material quality | Other |
Depth | 321 mm |
Type of motor | Electronically commutated (EC) |
Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
Max. air volume at 300 Pa | 135 m³/h |
Height | 1108 mm |
Suitable for extra VOC sensor | |
Material heat exchanger | Other |
Thermal efficiency according to EPN standard | 93.3 % |
Weight | 33.73 kg |
Supporting protocol for Modbus | |
Efficiency supply filter according to ISO 16890-1:2016 | 65 % |
Power input according to EPN standard | 0.0384 kW |
Housing material quality | Expanded polypropylene (EPP) |
With digital display | |
Number of phases | 1 |
Suitable for ceiling mounting | |
Suitable for ceiling mounting | |
Left/right orientation reversible | |
Left/right orientation reversible | |
Housing material | Steel |
With constant pressure control | |
Suitable for extra VOC sensor | |
With constant volume flow control | |
Power consumption at max. air volume at 100 Pa | 0.145 kW |
With heating element | |
Type of motor | Electronically commutated (EC) |
With digital display | |
With heating element | |
With bypass | |
Type of frost protection | Heating element |
With internal humidity (RH) sensor | |
Power electric heating element | 730-785 W |
Suitable for (extra) humidity (RH) sensor | |
Max. air volume at 300 Pa | 135 m³/h |
Voltage | 230 V |